AuthorPosts
-
October 31, 2015 at 8:00 pm #527955
Hello,
I’m having a problem with a table only when the page is publised
…strangely the draft version is displayed OK-> Page construction at draft stage
https://www.dropbox.com/s/5dwng3z824asuqb/OB%20table%20draft.JPG?dl=0-> What happen after publication
https://www.dropbox.com/s/hdqinqlr21rxhf3/OB%20table%20published.JPG?dl=0Thanks in advance for your support
FS
Table code :
[av_table purpose='tabular' pricing_table_design='avia_pricing_default' pricing_hidden_cells='' caption='' responsive_styling='avia_responsive_table' custom_class='']
[av_row row_style='avia-heading-row'][av_cell col_style=''][/av_cell][av_cell col_style='avia-center-col']OB-7/2 LT[/av_cell][av_cell col_style='avia-center-col']OB-22/2 LT[/av_cell][av_cell col_style='avia-center-col']OB-50/2 LT[/av_cell][/av_row]
[av_row row_style=''][av_cell col_style='']Dimensions externes en mm
(LxHxP)[/av_cell][av_cell col_style='avia-center-col']480 x 1080 x 470[/av_cell][av_cell col_style='avia-center-col']480 x 1080 x 470[/av_cell][av_cell col_style='avia-center-col']480 x 1080 x 470[/av_cell][/av_row]
[av_row row_style=''][av_cell col_style='']Dimensions internes du bain en mm
(diamètre x profondeur d’immersion)[/av_cell][av_cell col_style='avia-center-col']100 x 270[/av_cell][av_cell col_style='avia-center-col']147 x 500[/av_cell][av_cell col_style='avia-center-col']320 x 500[/av_cell][/av_row]
[av_row row_style=''][av_cell col_style='']Volume (L)[/av_cell][av_cell col_style='avia-center-col']~7[/av_cell][av_cell col_style='avia-center-col']~22[/av_cell][av_cell col_style='avia-center-col']~50[/av_cell][/av_row]
[av_row row_style=''][av_cell col_style='']Echelle de température (°C)[/av_cell][av_cell col_style='avia-center-col']-40 … +130[/av_cell][av_cell col_style='avia-center-col']-40 … +130[/av_cell][av_cell col_style='avia-center-col']-40 … +130[/av_cell][/av_row]
[av_row row_style=''][av_cell col_style='']Résolution d’affichage (°C)[/av_cell][av_cell col_style='avia-center-col']0,001[/av_cell][av_cell col_style='avia-center-col']0,001[/av_cell][av_cell col_style='avia-center-col']0,001[/av_cell][/av_row]
[av_row row_style=''][av_cell col_style='']Résolution de la consigne (°C)[/av_cell][av_cell col_style='avia-center-col']0,001[/av_cell][av_cell col_style='avia-center-col']0,001[/av_cell][av_cell col_style='avia-center-col']0,001[/av_cell][/av_row]
[av_row row_style=''][av_cell col_style='']Stabilité de température (°C)[/av_cell][av_cell col_style='avia-center-col']±0,004 @ -40°C
±0,005 @ 0°C
±0,002 @ 100°C[/av_cell][av_cell col_style='avia-center-col']±0,004 @ -40°C
±0,005 @ 0°C
±0,002 @ 100°C[/av_cell][av_cell col_style='avia-center-col']±0,004 @ -40°C
±0,005 @ 0°C
±0,002 @ 100°C[/av_cell][/av_row]
[av_row row_style=''][av_cell col_style='']Uniformité de température (°C)[/av_cell][av_cell col_style='avia-center-col']< ±0,007@-40°C[/av_cell][av_cell col_style='avia-center-col']< ±0,007@-40°C[/av_cell][av_cell col_style='avia-center-col']< ±0,007@-40°C[/av_cell][/av_row]
[av_row row_style=''][av_cell col_style='']Performance de chauffe[/av_cell][av_cell col_style='avia-center-col']37 min
(-40°C à 100°C)[/av_cell][av_cell col_style='avia-center-col']43 min
(-40°C à 100°C)[/av_cell][av_cell col_style='avia-center-col']61 min
(-40°C à 100°C)[/av_cell][/av_row]
[av_row row_style=''][av_cell col_style='']Performance de refroidissement[/av_cell][av_cell col_style='avia-center-col']64 min
(20°C à -40°C)[/av_cell][av_cell col_style='avia-center-col']100 min
(20°C à -40°C)[/av_cell][av_cell col_style='avia-center-col']121 min
(20°C à -40°C)[/av_cell][/av_row]
[av_row row_style=''][av_cell col_style='']Type de régulation[/av_cell][av_cell col_style='avia-center-col']PID[/av_cell][av_cell col_style='avia-center-col']PID[/av_cell][av_cell col_style='avia-center-col']PID[/av_cell][/av_row]
[av_row row_style=''][av_cell col_style='']Emission de bruit (dBA)[/av_cell][av_cell col_style='avia-center-col']< 58[/av_cell][av_cell col_style='avia-center-col']< 58[/av_cell][av_cell col_style='avia-center-col']< 58[/av_cell][/av_row]
[av_row row_style=''][av_cell col_style='']Système de refroidissement[/av_cell][av_cell col_style='avia-center-col']Compresseur[/av_cell][av_cell col_style='avia-center-col']Compresseur[/av_cell][av_cell col_style='avia-center-col']Compresseur[/av_cell][/av_row]
[av_row row_style=''][av_cell col_style='']Alimentation électrique[/av_cell][av_cell col_style='avia-center-col']230 V 50/60 HZ
(± 10%)[/av_cell][av_cell col_style='avia-center-col']230 V 50/60 HZ
(± 10%)[/av_cell][av_cell col_style='avia-center-col']230 V 50/60 HZ
(± 10%)[/av_cell][/av_row]
[av_row row_style=''][av_cell col_style='']Consommation (W)[/av_cell][av_cell col_style='avia-center-col']2000[/av_cell][av_cell col_style='avia-center-col']3200[/av_cell][av_cell col_style='avia-center-col']3200[/av_cell][/av_row]
[av_row row_style=''][av_cell col_style='']Interfaces[/av_cell][av_cell col_style='avia-center-col']RS 232 ou USB
ou Ethernet[/av_cell][av_cell col_style='avia-center-col']RS 232 ou USB
ou Ethernet[/av_cell][av_cell col_style='avia-center-col']RS 232 ou USB
ou Ethernet[/av_cell][/av_row]
[av_row row_style=''][av_cell col_style='']Poids (kg)[/av_cell][av_cell col_style='avia-center-col']82[/av_cell][av_cell col_style='avia-center-col']108[/av_cell][av_cell col_style='avia-center-col']133[/av_cell][/av_row]
[/av_table]- This topic was modified 9 years, 1 month ago by fensor2.
November 1, 2015 at 9:23 pm #528169I tryed to reduce the number of lines. From 18 to 8 lines. The issue disapear !
Isn’t it a bug in Enfold ?November 3, 2015 at 2:01 am #528928It appears that the sign “<;” is creating the issue
[av_row row_style=''][av_cell col_style='']Emission de bruit (dBA)[/av_cell][av_cell col_style='avia-center-col']< 58[/av_cell][av_cell col_style='avia-center-col']< 58[/av_cell][av_cell col_style='avia-center-col']< 58[/av_cell][/av_row]
Is there a way to show the sign “<;” ?
- This reply was modified 9 years, 1 month ago by fensor2.
November 3, 2015 at 2:05 am #528932November 3, 2015 at 2:30 am #528940Hi Yigit,
Thank you for your help but still creating a mess.
What charaters string to display < 58 into a table ?I tryed ” < 58″ but doesn’t work
[av_row row_style=''][av_cell col_style='']Emission de bruit (dBA)[/av_cell][av_cell col_style='avia-center-col']< 58[/av_cell][av_cell col_style='avia-center-col']< 58[/av_cell][av_cell col_style='avia-center-col']< 58[/av_cell][/av_row]
November 3, 2015 at 12:56 pm #529169Hi,
Please send us a temporary admin login so that we can have a closer look. You can post the details in the Private Content section of your reply.
Regards,
RikardNovember 3, 2015 at 1:35 pm #529216Here they are
November 4, 2015 at 2:03 pm #530005Hi!
are you sure this is the correct link where we can see the issue? because I can’t find the table in question.
Regards,
AndyNovember 12, 2015 at 1:02 am #534516Hi,
Could you try again please ?
Regards- This reply was modified 9 years, 1 month ago by fensor2.
November 16, 2015 at 5:06 pm #536653Hi!
I added this code before 58 in your table: “&# x3c;” without space and it does work for me now. Can you confirm please?
Cheers!
Andy- This reply was modified 9 years, 1 month ago by Andy.
-
AuthorPosts